Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Seeking inspiration to act upon it... The journey of creation!
Newsletter
Follow
Subscription Form

Is this the UK’s Most Leaky Roof?

The Leaky Legacy: Portcullis House and Its Ongoing Roof Woes

Is this the UK’s Most Leaky Roof?

Portcullis House, the prominent building that links the Houses of Parliament in London and accommodates 213 offices for politicians and their staff, has been plagued by persistent leaks since its opening in 2001. With a price tag of £235 million, the building’s roof has been an ongoing source of concern, requiring frequent repairs and refurbishments costing hundreds of thousands of pounds.

Unrelenting Roof Issues

This week, the roof of Portcullis House once again demonstrated its leaky reputation, with a cricket ball-sized hole appearing at the edge of a glass panel. The resulting deluge of rainwater cascaded down onto unsuspecting politicians, aides, and visitors during their lunchtime breaks on Tuesday 11 July. The sight of water gushing through the glazed roof caused chaos as people hurriedly sought shelter.

A Troubled History

Designed by architects Michael Hopkins and structural engineers from Arup, the atrium roof of Portcullis House faced a series of challenges within its first year. According to a 2002 report by the National Audit Office, a staggering 7,500 defects were recorded during that period. Subsequent issues emerged in 2005, 2008, 2010, 2011, 2013, and 2014.

A study in 2016 revealed that even slight movements in the roof were causing cracks in the glazing panels. In 2018, the problematic roof was debated in Parliament, with MP Vince Cable labeling the situation “scandalous.” However, plans to allocate an estimated £100 million for re-roofing the building were ultimately rejected.

Investigating the Latest Leak

A spokesperson for the parliamentary estate confirmed that investigations are underway to determine the cause of the recent leak. The affected area beneath the central part of the roof has been cordoned off while teams address the issue. Despite the incident, committee meetings continue as scheduled, albeit with revised access routes, and catering facilities remain open.

The Complex Structure of Portcullis House

Portcullis House features a central courtyard covered by the expansive atrium roof. The roof comprises a domed diagrid made of straight timber members with stainless steel joints. A delicate secondary web of steel struts and 6264 tension rods supports the frameless glass skin of the roof, creating an intricate architectural design.

Beneath the roof, a courtyard café and meeting area provide seating arrangements for visitors. In the past, the ground floor space was shaded by full-size trees, but their removal was necessary due to their limited root space. However, the building has garnered a reputation for overheating, partly attributed to the greenhouse effect created by the atrium roof.

Trouble in the Tolerances

The recurring problems with the roof, including shattered glass panels and persistent leaks, are believed to stem from tight tolerances between the roof’s metal, wood, glass, and supporting structures. Fluctuating temperatures outside cause movements within the framework, exerting pressure on the glazing. As a result, nearly 10% of the panels have cracked, leading to multiple leaks across the entire roof.

To mitigate potential hazards, shatter-proof film has been applied to the glazing, preventing it from fracturing into sharp shards. Nets have also been installed on occasion. Despite these measures, certain areas have had to be repeatedly cordoned off on the ground, and buckets have been strategically placed to catch leaks. These ongoing issues have proven embarrassing for MPs who frequently navigate the area while meeting important visitors and accessing parliamentary committee rooms. Recently, even Bank of England board members found themselves caught in the downpour within the building.

Highlighted Text:The recurring roof issues at Portcullis House have reached a point of absurdity,” remarks renowned architect Matthew Clarke. “It is essential that a comprehensive and lasting solution is implemented to ensure the safety and reputation of this prominent establishment.”

A Watertight Future for Portcullis House?

As the investigations into the latest leak unfold, it becomes increasingly evident that a long-term resolution is necessary to address the chronic roofing problems at Portcullis House. The need for a robust and durable solution is crucial to safeguard the integrity of the building and prevent future disruptions. Watch this space for updates on efforts to rectify the leaky legacy of Portcullis House.